8. Slide-in the PA board and place the grid back in place and screw in the
four black screws:
9. We now need to modify the grey plastic housing to make the fan fit:
10. We also need to modify the red IR plastic to make the fan fit:
11. WARNING! Put back the front plastic part on the G90 AND check is
the fan is spinning fine (free of mechanical stress) when the unit is powered
ON. This is a very important point. Since that the G90 spin detection hardware
is sometime lacking of the SilenX mis-rotation signal detection, this could let
the unit running while the blade is stopped by the 'miss-cut' front plastic part
(this will destroy your PA board because of overheat).
That's it! The fans should all run fine when the unit is powered up. The big
difference being how G90 is now even quieter than before (-7dBA) Enjoy!